Tuesday, January 6, 2009

RESULTS


 

 

 

 

Load F;

N

(F1+F2)

Boiler Pressure E;

kN/m2

 

Temperature of External water supply:

˚C

 

Motor speed (rpm)

Engine inlet pressure;

kN/m2

Boiler Temperature;

˚C

Condensation Rate;

mL/min

Condensation Temperature;

˚C

Calori-meter

T in

T out

 

1.0

360

27.8

35.5

1500

180

149.9

100

38.5

54.9

2.0

380

27.9

36.2

1500

200

152.4

135

45

69.9

3.0

400

28.0

36.9

1500

220

152.2

135

45

74.5

4.0

400

28.4

38.4

1500

260

152.1

150

51

83.6

5.0

380

28.7

38.7

1500

280

152.0

140

50

87.8

 

Table 1